NaviGuide 4000

Manual Ship Steering System

 

Ship Steering Control Unit


ENVIRONMENT


Ambient temperature range (operation) -15° C to +55° C
Ambient temperature range (storage) -25° C to +70° C
Protection grade IP32 to DIN 40050
Magnetic clearance I0.4 m
Environmental testing in accordance with EN 60945 (IEC 945 +A1)
Dimensions 151 mm Height
  392 mm Width
  425 mm Depth
Weight 3 kg
Power requirements 24 VDC (18 V to 36 V)
Maximum ripple content 4 V pp, extreme values should not exceed 36 V or fall below 18 V
Power consumption 10 W max
Reverse polarity protection built-in
Cable connection clamp-type terminals


Type Approval

The NAVIGUIDE 4000 Manual Steering System has been type approved by Germanischer Lloyd to IEC/EN 60945



INPUTS

 

Rudder order signal (follow-up hand wheel)

±10 V ±90° max rudder angle potentionmeter resistance 2kW with center tap

Rudder angle feedback signal ±10 V ±120° max rudder angle potentionmeter resistance 2kW with or without center tap
External system ±10 V ±120° max rudder angle
Speed input 200 p/nm or NMEA 0183
Steering mode status
Overrride status
Mute.
Central alarm NMEA 0183



OUTPUTS

DC Solenoid Valves

Outputs two for port, two for starboard (solid-state relays)
Type plus or minus switching
Voltage 12 VDC to 110 VDC
Rating 2.0 A max.
Additional outputs optional

or

AC solenoid valves

Outputs Two for port, two for starboard (solid-state relays)
Voltage
24 VAC to 230 VAC
Rating 1.0 A max.
Additional outputs optional

or

Proportional rudder order / error

Outputs

Two

80 mV/° to 350 mV/° (isolated) or

4 mA to 20 mA (isolated)

Additional outputs
optional

or

Proportional solenoid valves

Outputs One for port, one for starboard
Rating
1.6 A max.
Additional outputs optional

OUTPUTS AND INTERFACES


CAN to IEC 61162-3 for bus interface units and additional follow-up amplifier

Central alarm NMEA 0183
Voyage Data Recorder (VDR)


Status and alarm outputs

System alarm potential-free contacts
Override alarm
2 A maximum current
External system status 250 V maximum voltage
Deadman's control
Mute

 

Power failure alarm

Primary supply potential-free contacts
Backup supply 2 A maximum current, 250 V maximum voltage